ClearWater OzoneMAX OZ-50 Manuel d'installation et d'utilisation - Page 3
Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} ClearWater OzoneMAX OZ-50. ClearWater OzoneMAX OZ-50 8 pages. Vacuum-ultraviolet pool ozone systems
Power Source/
TimerBox
The OzoneMAX system is comprised of a power box and a venturi injection kit with manifold, which
needs to be installed at the very end of the return line (after the filter, ionizer electrode chamber,
heater, etc.).
The ozone unit will need to be installed to a post or wall within six (6) feet of a 115 or 220VAC timer,
electrical box or a 115V receptacle. This location will need to be within eight (8) feet of location of the
venturi injector. This location should be mounted at least one (1) foot above maximum water level
and preferably out of direct sunlight. The ozone unit should be no closer than five (5) feet from a
body of water.
Mount the OzoneMAX unit to a post or wall using the four mounting screw holes in the enclosure
base. The unit may be mounted horizontally or vertically, however it is recommended that the vent
holes not face upward and be directly exposed to rainfall. The location of the box must be within
eight (8) feet of the location of the venturi, which is plumbed on the return line. The unit should be
mounted at least one (1) foot above maximum water level and preferably out of direct sunlight. The
power box should also be located no closer than five (5) feet from a body of water.
It is strongly recommended to add a protective shade cover to keep the unit out of direct
sunlight if possible.
C. Tools & Materials Required
• Bullet Level
• Hacksaw or Pipe Cutter
• PVC Cleaner/Primer
• Screwdrivers, Flat & Phillips
D. Site Survey
OzoneMAX Unit
within 6 feet
E. Installing the Power Box
• Drill & Drill Bits
• PVC Cement
• Utility Knife
• Screws & Anchors
within 8 feet
3
Venturi Injector