4.1 MECHANICAL

Height ....................................................................................... 4.50 inches
LMD602 (T) Width .................................................................... 1.14 inches
LMD604 (T) Width .................................................................... 2.34 inches
Depth (excluding handle) ..........................................................6.875 inches

4.2 ENVIRONMENTAL

Storage Temperature Range ................................................... -45 to +85
Operating Temperature Range ................................................ -34 to +74
Humidity Range (non-condensing) .................................... 0 to 95% Relative

4.3 ELECTRICAL

DC Supply Voltage Minimum.......................................................... 10.8 Vdc
DC Supply Voltage Maximum......................................................... 28.8 Vdc
DC Supply Current .......................................................... 100 mA Maximum
DC Inputs
True (low) ...................................................................... less than 8 Vdc
False (high) ............................................................ greater than 16 Vdc
Optically Isolated Solid State Outputs
True (low, 50 mA) ....................................................... less than 1.5 Vdc
Maximum Leakage Current (DC Supply = 24Vdc) ......................... 10 uA
Maximum Current (low) ............................................................. 100 mA
Relay Outputs
AC Contact Rating .......................................................... 5A @ 120 Vac
DC Contact Rating ............................................................ 5A @ 30 Vdc

4.4 TUNING

4.4.1 LOOP INDUCTANCE (TUNING) RANGE

The detector will automatically tune to a loop and lead-in combination within the tuning
range of 20 to 2500 microHenry with a Q factor greater than 5.

4.4.2 ENVIRONMENTAL TRACKING

The detector automatically and continuously compensates for component drift and
environmental effects throughout the tuning range and across the entire temperature range.

4.4.3 GROUNDED LOOP OPERATION

Each detector channel will operate when connected to poor quality loops including those
that have a short to ground at a single point.

4.4.4 LEAD-IN LENGTH

The unit will operate with lead-in (feeder) lengths up to 5,000 feet (1,524 m.) with
appropriate loops and proper lead-in cable.

4.5 LOOP INPUT (LIGHTNING PROTECTION)

The loop input incorporates lightning and transient protection devices and the loop
oscillator circuitry is transformer-isolated for each channel. The lightning protection will