EDI 244L Manuel d'utilisation - Page 7
Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} EDI 244L. EDI 244L 8 pages. Dc isolator unit
a.
Input voltage or pulse width does not meet the requirements of section 1.7.3 or
1.7.4.
Verify that the DC input voltage level is less than the DC Inputs True specification.
Verify that the DC input pulse width is greater than the Input Pulse Width Accept
specification.
1.6.2 TROUBLE SHOOTING SEQUENCE
Apply 24 Vdc nominal power to DC POWER pin J1-B referenced to LOGIC GROUND pin J1-
A. Connect a jumper circuit to the DC inputs J1-D (J1-J) and J1-E (J1-K) to simulate the
closure of the input contacts. The following signal measurements are referenced to test point
CH1 (CH2).
NOTE: internal test point "GND" is isolated from Logic Ground. Care should be exercised in
probing internal test points.
a.
Input Bias Power Supply VCC
Voltage at test point VCC should be 19 1 Vdc with respect to GND.
Possible component faults are: controller U18, CR12, R14, transformer T1, CR30,
reference U25, or opto-coupler U21.
b.
Regulated Power Supply VDD
Voltage at test point VDD should be 5 0.2 Vdc with respect to GND.
Possible component faults are: voltage regulator U26, inductor L2, diode CR29.
c.
Microcontroller
Possible components at fault are: microcontroller U20.
d.
Output Circuit
Output signals are processed by the microcontroller U20 and appear at U20.10
(U20.9) and on the display LEDs but are not appearing at the output pins.
Possible components at fault are: opto-coupler U8 (U9), transistor Q7 (Q8).
1.7 SPECIFICATIONS
1.7.1 MECHANICAL
Height ........................................................................................................4.50 inches
Width (242L) ............................................................................................... 1.2 inches
Width (244L) ............................................................................................... 1.2 inches
Depth (excluding handle) ......................................................................... 6.875 inches
1.7.2 ENVIRONMENTAL
Storage Temperature Range ................................................................. -45 to +85
Operating Temperature Range .............................................................. -34 to +74
Humidity Range (non-condensing) ................................................... 0 to 95% Relative
1.7.3 ELECTRICAL
DC Supply Voltage Minimum ......................................................................... 10.8 Vdc
DC Supply Voltage Maximum ........................................................................ 28.0 Vdc
DC Supply Power Maximum ......................................................................... 2.0 Watts
DC Inputs
True (low) ................................................................................... less than 8 Vdc
False (high) .......................................................................... greater than 12 Vdc
Optically Isolated Solid State Outputs
True (low, 50 mA) ..................................................................... less than 1.5 Vdc
False (high) .......................................................................... greater than 16 Vdc
Maximum Leakage Current (high) ................................................. less than 1 uA
Maximum Current ..................................................................................... 50 mA
Collector Voltage Maximum ......................................................................50 Vdc
Eberle Design Inc.
o
C
o
C
Page 4