Altronics PowerQuest Manuel - Page 3
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Altronics PowerQuest. Altronics PowerQuest 6 pages. Touch screen control system
Également pour Altronics PowerQuest : Manuel de démarrage rapide (6 pages)
Configure:
System will be Configured with default settings. To change those settings press the "Config" button on the switch panel screen.
Brightness
– Turns screen off, will not change settings. Press anywhere on screen to turn
Sleep
back on.
Select
1411 S. Roselle Rd. Schaumburg, IL 60193
www.AltronicsInc.com
– Sets screen brightness
Channel- Press to see list of available channels, then select channel to modify
Not all features are available for all circuits.
Channel –
Displays channel name. Aux1 and Aux 2 are modifiable.
Max
Current: Select maximum fused amperage for circuit (0-30amps).
Soft
Start: Check box to allow slow increase in current at turn on.
Limit Enabled:
Check box to limit circuit turn on by temperature settings
(Fan or Water Only)
Temperature:
Select temperature to enable.
Hysteresis:
Differential temperature change required to activate.
(
Ex: With a 2º hysteresis and a 100º temperature setting the controller will allow
the actual temperature to go to 98º before turning off Fan and Pump and back to
100º to turn on again)
Auto Switch:
Check box to enable. Allows circuit to automatically
Enable after a set delay time, once Start button is
pressed. Also allows circuit to Disable when Ignition
button is turned off.
Auto Switch Delay:
Time in seconds circuit is delayed from turning
Save:
Saves changes and returns to previous Menu.
Phone (847) 923-0002 Fax (847) 923-0004
on after Start button is pressed.