Artico SY-AC900 Manuel de l'utilisateur - Page 11

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Artico SY-AC900. Artico SY-AC900 16 pages.
Également pour Artico SY-AC900 : Manuel de l'utilisateur (13 pages)

• Timer
:
Press the Timer key to set the time. The first 5 hours can be set in intervals of 30 minutes. The
remaining hours can only be set in fractions of hours. Once the timer has been set, the number will
blink 5 times on the remote control to confirm the setting.
Max. Cool
:
Under cooling mode, press the Max key to achieve the maximum output.
• Keypad lock: Use a thin pointed device to lock the buttons of the remote control. A lock appears on
the display as per the following picture
and be able to use the remote control again. (This function can prevent children from using the unit
without supervision)
• Reset: Use a thin pointed device to press the "Reset" key on the remote control. The remote will set
all its parameters back to the default settings.
Important Note:
• Never turn off the air conditioner by unplugging it from the power supply or pulling it from
the cord. Always press the "On/Off" button and wait a few minutes before unplugging it. This
allows the device to perform a check cycle to verify operation.
Anti-freezing protection control
When in Cooling mode, if the compressor has worked for over 10 minutes and the copper coil
temperature is continuously <2ºC for over 20 seconds, then the compressor and water motor will stop
working and the LCD will display E4. The unit at this moment initiates the anti-frost protection and all
buttons on the control panel (except for power button) are inactive.
Once the copper coil temperature increases back to >8ºC, the anti-freezing protection will stop
automatically and the compressor, water motor will start working once again and the machine will
recover back to its previous operating state, (in order to protect the compressor, it will be restarted 3min.
later)
Water-full protection
When the water level in the water plate exceeds the warning level, the machine will alert the user
automatically and the LCD will display "FL". You will need to drain the water from the machine following
the section of "Water Drainage"
Compressor delay-protection
The compressor will always have a small delay of about 3 minutes in order for it to begin. This means
that the compressor is in recovery mode. Only during the first use of the unit, the compressor will come
on immediately.
. Press the same key once again to unlock all the buttons