djpower TOPCAT CAT-2 Manuel de l'utilisateur - Page 10
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} djpower TOPCAT CAT-2. djpower TOPCAT CAT-2 13 pages.
5.5
Three working mode
•
Down mode
The fan beneath the nozzle is working in this mode, and its speed is can be adjusted through the LCD display or "DMX".
•
Up mode
The fan above the nozzle is working in this mode, and its speed is can be adjusted through the LCD display or "DMX".
•
Forward mode
Under this mode, both fans are defaulted OFF. Fans' speed can not be adjusted through the LCD display or "DMX".
•
Self-Clean mode
When the unit is out of DMX control for 15 seconds, or if holding "ENTER" button for 3 seconds, the unit will enter into Self-Clean mode.
The display will show a countdown as you hold the enter button. Then, after it counts down from 3 to 0, the auto clean mode is engaged. It
should take 180 seconds for cleaning. Then, the unit will go into standby mode. The display will go black until the user presses an buttons or
connects DMX control. Then, the unit will wake up again. Under clean mode, Press any buttons or input DMX signal can exit clean mode.
5.6
Auto Run Last Settings
If the machine is shut off while it is operating at standalone mode (On-device manual control), the "Auto Run Last Setting" will allow the
machine to recover its previous same operating status when the unit is powered on again without pressing any button.
• Shut off: Get disconnected from power supply or turn off the power switch
• Power on: Get connected with power supply or turn on the power switch
5.7
Fluid Sensor
This machine uses software-based fluid sensor to detect whether there is fluid inside tube so as to protect the pump from being damaged.
Turn on the "Fluid Sensor" to activate "No Fluid Protection" function.
Trigger "No-Fluid Protection"
5.8
When the Fluid Sensor is ON, the software-based "no-fluid protection" function will be activated. After the program continues to detect the
machine working with no fluid inside the tube for 60 s, the pump-shutoff will be activated with the flickering warning page showing on the
screen.
Clear "No-Fluid Protection" Warning
5.9
When the machine is under the no-fluid protection, after refilling the fluid, there are three ways to clear the warning.
•
Press<ENTER> first, then press<VOLUME> to let the machine run again, the warning will disappear until the fluid is pumped and fill the
tube.
Self-Clean
ON
Fluid Sensor
ON