Troubleshooting
Problem
Alarm is not activated
although someone is
walking in detection
area
Alarm is activated with
nobody in the area
LED does not light up
at the time of the walk
test
LED does not light up
in normal operation
Pro Tips
Save battery life by taking unit out of walk test mode after
completing walk test. There is no 2 minute delay when
in walk test mode. Leaving in walk test mode will
severely decrease battery life.
Light changes will cause the sensor to trip. Ensure that the
detector is not placed near windows.
Sudden temperature changes will cause the sensor to trip.
Ensure the motion detector is not placed near heating
and cooling vents.
High humidity environments can cause condensation of
the detection lens. Ensure the motion detector is not
installed in these kinds of environments.
Protective film should be removed from the lens after
installation.
Sensor Specifications: The table below displays the
functional frequencies of each compatible sensor.
Probable Cause
Detection area is improper,
battery is dead, Walk Test
switch is OFF and 2 minute
delay is active
Moving object within
detection area, temperature
of object within area is
changing rapidly
Walk test switch is OFF,
battery is dead
LED switch is OFF, battery
is dead
Remedy
Conduct a walk test, change
the battery
Remove the object from
the detection area, remove
the heat sources from the
detection area or relocate the
detector
Turn the walk test switch ON,
change the battery
Turn LED switch ON, change
battery