Alula RE109 Manuel d'installation

Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Alula RE109. Alula RE109 2 pages.

Alula RE109 Manuel d'installation
Resolution Compatibles
The Glassbreak
breaking glass and sends alarm signals to the security panel.
Features
• 360 degree Omni-directional coverage
• Optional external contact
• Low battery indication
• 5-year warranty
Enroll
by placing the panel into wireless enrollment mode and
removing the battery tab or pressing the enrollment button.
Alternatively, the sensor can be enrolled by entering its
8-character serial number on the interactive service provider's
web portal.
Options for sending an Enrollment Signal
• Remove the battery tab, OR
• Press the enrollment button
Install
by mounting the sensor at least 3 feet (~1 m), but
no more than 25 feet (~7.5m), from a window using the
mounting screw locations or VHB tape. Ensure that the
sensor has visual line-of-sight to all of the windows being
protected.
Optional External Contact may be enrolled as an additional
zone. In order to use the external contact, it must be
enabled using the interactive service provider's web portal.
External Contact
• Connect the external contact to terminal
B and the middle terminal
• Use only a normally-closed contact
• Do not use end-of-line resistors
Pro Tips
3M VHB Tape works great if the surface is properly prepared
and firm pressure is applied for over 10 seconds.
Surface Preparation
• Clean the surface
• Ensure the mounting surface temperature is
above 50 °F
LED blinks when the sensor detects breaking glass.
Glassbreak Testers should be used to verify operation after
enrollment and installation.
Use the panel installation guide to verify proper system setup.
is a security sensor that detects the sound of
RE109 Glassbreak
Interlogix
®
Compatible
External Contact
Terminal Block
I
Enroll Button
LED