Alula RE609-CE Manuel de démarrage rapide
Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} Alula RE609-CE. Alula RE609-CE 2 pages.
The RE609 Glassbreak
breaking glass and sends alarm signals to the security panel.
Features
• 360 degree omni-directional coverage
• Optional external contact
• Low battery indication
• 5-year warranty
Enroll
by placing the panel into wireless enrollment mode and sending
an enrollment signal. Alternatively, the sensor can be enrolled by
scanning its bar code using the Connect+ Installer App or by entering
its 8-character serial number on the interactive service provider's web
portal.
Sending an Enrollment Signal
• Remove the battery tab and press the
enrollment button
Install
by mounting the sensor at least 3 feet (~1 m), but no more than
25 feet (~7.5m), from a window using the mounting screw locations
or VHB tape. Ensure that the sensor has visual line-of-sight to all
windows being protected.
Glassbreak Testers
enrollment and installation (use any glassbreak tester).
• Putting Sensor in Test Mode:
1. Put tester on tempered setting.
2. Hold tester next to the microphone and activate tester.
3. The red LED will light for 4 seconds.
4. Sensor sends alarm to control panel.
• Red LED will blink one time per second for one minute (Test Mode).
• Every time the sensor hears the tester in Test Mode, the red LED
will light for four seconds and sensor sends alarm.
• In Test Mode:
1. Test sensor distance – holding tester near surface of the
window protected, activate tester with speaker pointed
towards sensor.
2. If the red LED does not light for 4 seconds, relocate sensor
and retest.
3. When location is verified and a good test is confirmed, the
red LED will stop blinking 1 minute after last tester sound
it hears.
NOTE: The pattern recognition technology of this sensor
ignores most false alarm sounds, including glassbreak
testers (except in test mode).
Optional External Contact
In order to use the external contact, it must be enabled using the
Connect+ Installer App or the interactive service provider's web
portal.
External Contact
• Connect the external contact to terminal B
and the middle terminal
• Use only a normally-closed contact
• Do not use end-of-line resistors
Use the panel installation guide to verify proper system setup.
RE609 Glassbreak
Connect+
is a security sensor that detects the sound of
should be used to verify operation after
may be enrolled as an additional zone.
Encrypted
™
External Contact
Terminal Block
I
Enroll Button
LED