IMPORTANT NOTICES
This manual is used as a supplement to the installation instructions that are provided with the
vehicular gate operator. This manual references only the battery backup system and its connections
to the vehicular gate operator. Refer to the operator installation manual for all other instructions.
The optional battery backup system installed in your vehicular gate operator is designed as a
convenience enhancement only. It is not designed or intended to provide continuous gate operation
during a power outage. Its sole purpose is to provide a method to open the vehicular gate to allow
unimpeded traffic flow when the gate and access control system is without power.
If your access control system requires 100% power backup and continuous operation when primary
(AC) power has failed, a power inverter / backup system, such as DoorKing's Model 2000, is
required.
•
The battery backup system cannot provide continuous gate operation during a power outage.
•
Operation of this system is limited to cycling the gate to the open (up) position one time only.
•
The battery backup system requires testing on a monthly basis to insure the batteries are
fully charged and that the system is operational.
•
The battery backup system uses two 12-volt, 3.0 amp-hour gel-cell batteries. These batteries
should be replaced every two years on average, or sooner if required.
•
Batteries are affected by temperature. Cold temperatures will reduce the effectiveness of the
batteries and the backup system. High temperatures will result in a shortened battery life.
•
Batteries are not covered under warranty.