Attach twin ground
cable here
Attach the twin ground cable to the workpiece with the "C" clamp. Connect the other end of the cable to
1.
the left socket on the CLASSIC panel.
2.
Connect the Control Plug (7 pin connector) on the Gun cable, to the 7 Pin Socket on the front panel of
the CLASSIC.
3.
Connect the Weld Cable Plug on the Gun cable to the right socket on the front of the CLASSIC.
4.
Connect the power lead to a 120 volt supply.
NOTE: UNIT IS SHIPPED FROM THE FACTORY TAPPED FOR 120 VOLT OPERATION. FOR 220/240 VOLT
OPERATION THE TRANSFORMER MUST BE RE-TAPPED. CALL CUTLASS FOR THE CORRECT PROCEDURE.
COPYRIGHT CFI 2009
Cutlass Fasteners, Inc.
83 Vermont Ave., Unit 6, Warwick, RI 02888
Tel: (401) 732-6333 Fax: (401) 732-6336
cutlass-studwelding.com
CLASSIC+ CD MANUAL
HOW TO INSTALL YOUR CUTLASS CLASSIC
email:
Stud Welding...
Fasteners
Equipment
Service
Attach gun control
cable here
Attach gun weld
cable here