Magnetic / Electric Strike Lock Wiring

Magnetic Lock Specifications

If a magnetic lock is used, the lock and wires are located on the gate frame towards the top of the gate door.
[Figure 5]
Magetic Lock (Standard):
Voltage:
Current:
Switch Contact:
Holding Force:
Wire Lead:
• Red -
• Black -

Electric Strike Lock Specifications

If an electric strike lock is used, (2) two white wires attached to the lock will be coming out of the wire access hole.
Either side of the access hole can be plugged if necessary. A 1/2" pipe thread hole plug is supplied. [Figure 6]
Electric Strike Lock (Standard):
Voltage:
Current:
Switch Contact:
Wire Lead:
• Red -
• Black -
NOTE
• Normally Open refers to Fail Lock & Normally Closed refers to Fail Safe.
• Cable runs are not to exceed 50 feet.
Page 10
+12VDC
0.25A
Normally Closed
1200lbs.
+12VDC Input
Ground
+12VDC
0.25A
Normally Open
Normally Closed
+12VDC Input
Ground