Alvarado IntraQ-X Manuel d'installation - Page 17
Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Alvarado IntraQ-X. Alvarado IntraQ-X 20 pages.
Troubleshooting
Device doesn't power on.
When you press the power switch on the IntraQ-X, the unit does not power on.
Potential Cause
The Ethernet cable is unplugged at the POE switch.
The 12V fuse is blown (Amanda DC boards only).
The Ethernet cable is unplugged at the IntraQ-X's
Ethernet port.
The Ethernet cable is bad.
The Ethernet connector on the board is bad.
Page 17
For Assistance: [email protected] +1 (909) 591-8431
IntraQ-X Installtion Guide Version 2.0
IntraQ-X Installtion Guide Version 2.0
Solution
Check the POE switch and verify the cable is plugged in.
Verify the POE switch is on.
Check the 12V fuse for continuity.
Replace the 12V fuse.
Remove the case and verify the Ethernet cable is
plugged into the POE splitter.
Replace the Ethernet cable.
Contact Alvarado.
PUD4253R3-0