Defect
No air come out from the air
bubble stone
Air flows out but no ozone
Strange noises while
working
7. Ozonation process
BEFORE STARTING THE OZONATION PLEASE READ ALL INFORMATION BELOW.
7.1 Room preparation before ozonation
-
Locate and dispose of source of the problem
-
Take any animals or plants out of the room
-
Make sure the room is hermetic (e.g. ventilation vents, doors etc.)
-
Take out any works of art.
-
Any valuable things can be protected with a stretch foil (e. g. RTV equipment)
7.2 Setting up the device
During the ozonation process thee device should be placed at a higher level (not on the floor,
ozone is heavier than air) To better spread the ozone we can use additional fans.
Leave the room and make sure that nobody enters during the ozonation process.
7.3 Process Monitoring
It is recommended to regularly check if the working area stays hermetic, the ozone should
not diffuse to any outside places like a staircase.
7.4 Finishing the Ozonation
After the generator turns off, wait 30 minutes in order to utilize the prepared ozone. If the
space will be used after the process, ventilate the room for around 15 to 20 minutes until the
ozone concentration is safe (0.1ppm).
AIO - Instruction of use, Version 2, Date: 16.06.2020
Analysis
Check silicone hose for
leakage or folds
Check whether air bubble
stone is blocked
Ozone generator fails to
work
Not enough water
Resonance with the desk
Solution
Smooth the hose or change
a new one
Change to a new one
Contact the manufacturer or
representative
During water ozonation:
Ozone can be easier to
resolve in water when water
depth range is between 20
cm and 40 cm. It can have a
better sterilizing effect.
Place a stable desk
13/16