NOTE: Calibration is a critical step in setting up your scanner. This process will balance the image quality between
your computer and the scanner unit. If at any time you switch the scanner to another computer then you will need
to reinstall the scanner driver and recalibrate the scanner.
Selecting Scanning Source
a) When using Presto! PageManager 7 for the first time you will need to define the Scanning Source
this application will be using. This also applies when switching to another scanner.
b) Run the PageManger7 application and select file in the toolbar menu.
c) Under file pull-down menu choose the Select Source option, then your model.
Performing Scanner Calibration under TWAIN
a) Tools Scan Settings uncheck Suppress TWAIN User Interface
b) To calibrate your scanner select the Acquire Image Data icon (scanner and camera icon) under the
toolbar menu.
a) The TWAIN user interface screen will appear.
b) Insert the calibration target with the printed arrow end first.
c) Make sure the black bar side is inserted facing down then select the Calibration button.
NOTE: When the image quality has become unsatisfactory, we recommend you clean the scanner with the included cleaning
sheet(see Tips & Cautions page) and then recalibrate the scanner.
If you lose or forget the calibration target when traveling, use any plain "white" piece of printer paper to perform the
calibration. The following message will appear (see below). Select "OK" and proceed to scanning.