The f ixed point of the pipeline should be determined when using rigid piping so that
suff icient expansion of the collector header pipe is possible. The rigid piping must NOT
be shortened. The continuing connections must be supported after a length of max. 15 cm.
Notes on the continuing pipeline
Do not solder on the collector and the supplied terminals. The design of the collector
must not be changed.
For installation, use only components that are suitable for the high temperatures that
occur, for example, gunmetal and brass f ittings, copper and stainless steel pipe.
When using hemp, use only pressure and temperature resistant solar sealant.
When using compression f ittings, all tube ends must be square and deburred. Push the
union nut and the clamping ring onto the tube and wet the threads with a little oil. Push
the tube as far as it will go into the compression f itting. First tighten the
union nut by hand and then tighten by ¾ turn.
Mounting the sensor
-
insert the sensor into the sensor immersion sleeve
-
connect with heat shrink tubing
-
shrink the shrink tubing with a heat source or wrap it with the protective f ilm provided