Signal Processing
Signal Processing
Temperature
The temperature of a venue also plays a crucial role in affecting the Room delay. The SR 400 D allows you to enter in
the current room temperature. Once the correct temperature is entered, the SR 400 D will re-calculate the Room
delay so the correct delay is used.
The procedure for changing the Temperature of the SR 400 is as follows:
From performance mode, press the <Utility> button and use the <Bypass> and <Mode> button to scroll to the
Temperature setting. Now depending on the Temperature Unit Selection (Page 6), the the temperature will either
read in Celsius (0 to 30 degrees)or Fahrenheit (32 to 86 degrees). Now use the <Data Wheel> to select the
desired temperature. Once selected, the SR 400 D will re-calculate and the correct Delay is heard.
Note: This utility function can only be used when the Delay Unit is being measured in Feet or Meters.
Factory Reset
To Factory reset the SR 400 D to its original default settings, you must perform the following procedure.
Press and hold the <Bypass> button while supplying power to the unit. The display reads: Reset SR 400D? Now
release the <Bypass> button and press the <Delay 2> button. The SR 400 D will now be returned to its original
default settings.
Specifications
A/D/A Resolution: 18/16 bit
Frequency Response: 20 - 16 kHz
THD: .08%
Signal-To-Noise Ratio: 90dB (typical)
Input Impedance: 40 kΩ balanced
Output Impedance: 100Ω balanced
Weight: 3.3 Lbs - 1.5 Kg
Dimensions:
1.75" X 4.75" X 19"
Power Supply: 9 VAC @ 750 mA
7