Acqua GY-NE200CF Manuel d'instruction - Page 7
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Acqua GY-NE200CF. Acqua GY-NE200CF 10 pages.
INSTRUCTION MANUAL
BEFORE REQUESTINGSERVICE
Please check the following items if you encounter problems with the unit. If the problem continues after
taking the proper remedial actions, disconnect the power cord plug from the wall outlet.
Transfer the items stored in the cooler to a box or other container. Then contact the dealer from whom
you purchased this unit and be ready to provide information as listed in "REQUIRED INFORMATION"
below.
T o prevent any electrical shock hazards, do not disconnect the power cord plug from
the wall outlet with wet hands.
CAUTION
No refrigeration
at all
Inadequate
refrigeration
Excessive noise
Condensation
on cooler
exterior
The circumference
of chest freezer
feels hot
Appliance sometimes stops running when thermostat turns o .
Is the power supply interrupted?
Is the power cord plug disconnected from the wall outlet?
Are the power fuses blown and/or the circuit breaker activated?
Is the temperature control dial turned to OFF?
Is the place of installation badly ventilated?
Is the freezer exposed to direct sunlight, placed near a heater or stove?
Are the lids opened and closed frequently?
Are items stocked beyond the load line?
Is the temperature control dial turned to MIN?
Much frost formed in the chest freezer?
Is the floor underneath the freezer sturdy enough?
Is the unit shaking and rattling?
Is the rear panel of the unit touching the wall, etc.?
A container or something is behind the chest freezer?
The compressor will generate a rather lound sound for a while after operation is
started. This noise will cease.
Condensation may collect on the exterior and door during hot and humid
days or depending on the place of installation. This occurs when the humidity
is high and water particles in the air contact cold surfaces. This is normal.
wipe away condensation with a dry cloth.
Especially in summer or initial operation, the circumference of chest freezer can
Feel hot. Because chest freezer inside has a pipe for radiating and preventing
condensation.
This heat does not e ect the inside goods.
Pipe
6