Dodge Para-Flex GT Manuel d'instruction - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Dodge Para-Flex GT. Dodge Para-Flex GT 4 pages.
(1)
If flanges are being re-used, clean flange mounting area as well as flexible element seats with a solvent, such as Xylene (Xylol), to remove
grease, oil, and dirt from surfaces. A diluted soapy water solution may be applied to aid with element installation.
(2)
Loosen clamp ring nut so the element toe can seat within the clamp ring faces. Wrap flexible element around flanges as shown. Make sure the toe
of the element is fully worked down into the flange and seats on the hub. To ensure proper seating, rap around the tire's outside diameter with a
small mallet until split is closed. Make sure element is evenly centered on the flanges.
(3)
Hold split closed and tighten clamp ring nuts by hand. Using both hands, knead the tire pulling it toward the split and tighten clamp ring nuts
further to hand-tight.
(4)
Tighten hex-head micro-mount screws to the torque shown in Table 6.
NOTE: The bottom of the hex-head cap screws should compress the lockwasher beneath the head. If the lockwasher is not compressed then the
locknuts should be loosened 1/8 turn. To accomplish this, loosen hex-head cap screws and rotate locknut(s) 1/8 turn in the counterclockwise
direction. Repeat item 4 above.
Section 4a – Flexible Element Replacement
(1)
Loosen hex-head micro mount screws.
(2)
Loosen clamp ring nuts by rotating counter clockwise.
(3)
Grasp one end of flexible element at the split and peel it off the flanges.
(4)
Clean clamping parts with a solvent, such as Xylene (Xylol), to remove grease, oil, wax and dirt from surfaces.
(5)
Realign coupling and install new flexible element according to Section 4.
www.baldor.com www.ptplace.com
Baldor Electric Company Headquarters
P.O. Box 2400, Fort Smith, AR 72902-2400 U.S.A., Ph: (1) 479.648.5792, Fax (1) 479.648.5792, International Fax (1) 479.648.5895
Baldor - DODGE/Reliance
6040 Ponders Court, Greenville, SC 29615-4617 U.S.A., Ph: (1) 864.297.4800, FAX: (1) 864.281.2433
5/07
Copyright © 2007 Baldor Electric Company
Section 4 – Flexible Element Installation
Table 6
Size
50
60
80
5/16-18 x 1-1/8
www.dodge-pt.com
www.reliance.com
All Rights Reserved. Printed in USA.
Micro-mount Screw
Size
Torque
M6 x 18mm
130 in-lbs
1/4-20 x 7/8
140 in-lbs
290 in-lbs
This material is not intended to provide operational instructions. Appropriate instruction manuals and precautions
should be studied prior to installation, operation or maintenance of equipment.