DOGA GX220P Manuel d'instruction - Page 10
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} DOGA GX220P. DOGA GX220P 16 pages. 40 volts
10.3 Angle control & Auto reverse ( GXT____ )
Model : GXT150, GXT220, GXT450
One triggering by the lever can make 3 step operation sequence in a cycle
■
Start, Stop and Direction in a cycle
Step
Sequence
Rotating
Counterclockwise by F/R
direction
Screwdriver runs to the
target angle and stop. It
Activating
always stops at the set
torque, even it does not
reach the target angle.
Time setting
0 - 5 sec / 30 steps
- Screwdriver stops Immediately when the lever is released in any sequence.
- Sliding F/R switch works for
■
Operating (Work) mode
① Rotating direction (FOR-REV)
■
PROGRAM mode
① First run angle (Increase / Decrease) together with "First Run(Speed)" button
② Time (Increase / Decrease) together with "Stop(Reverse)" button
③ Rotation speed (Increase / Decrease) together with "Speed(First Run)" button
④ Reverse run angle (Increase / Decrease) together with "Reverse(Stop)" button
Instructions manual / GX Screwdrivers
1
first RUN
Clockwise or
switch
→
2
stop HOLD
Stop and hold for set time
0 - 5 sec / 12 steps
→
3
reverse RUN
Reverse
Rotate reverse until
releasing the lever or
stop at the target torque
x
10