POSITIONING THE TANK
If there is very little room between the top of the tank and the floor of the building,
the order of the installation can be changed as follows: Firstly, cut the hole for
the pedestal in the floor of the building (refer to page 9, Toilet Chute & Pedestal).
Position the tank under the hole and then mark the position of the hole onto the
tank. After the tank has been marked, it can be removed from under the building.
Cut the hole in the tank and fit the chute collar before placing the tank back into
position.
Check the position planned for the toilet chute. The toilet chute must be
positioned over the top of the compost tank. For less maintenance of the
compost pile, the optimum location for the chute/s to enter the tank is mid-
width, in the rear half of the tank. A clearance of at least 150mm from edge of
chute to edge of tank-top is desirable to avoid rapid build up of the pile against
the sides.
Check there are no major support beams, pipes or electrical wire that are in the
way of the toilet chute.
Where mains power is to be used, check that a power point has been installed
near the location for the ventilation fan.
Locate where the excess liquid drainpipe and tench is to go and take this into
account when positioning the tank.
TANK SUPPORT
The composting tank must be supported by either packed earth with the tank
placed on a base of sand, or a wooden frame on a solid base (e.g. a concrete slab).
Insulation between the tank and the concrete slab will reduce heat loss and aid the
composting process.
NOTE: The tank and enclosure should be protected from surface water and
floodwater.
Smooth Ground
50-75mm bed of sand, crusher dust
or similar solid sub-soil
IMCM-40-2023-12-04
ecoflo.com.au
1300-138-182
Uneven Ground
6