Counting Set-Up Instructions (Continued)
Push both UP+DOWN set up the buzzer:
ON
Fastening a screw, completing work and mistaken operation, buzzer
will be on.
OFF
Wrong operation will be buzzed.
FF
Work completed and wrong operation will cause buzz.
EF
As one screw is fastened and work is completed, buzzer will be on; as
mistake made has no buzz.
Ht/Lt Description:
•
Ht/Lt sets up the period of time. If the tool stops within the set period, it means
OK. In contrast, it will be (NG) if it stops before Lt or after Ht. The LT accepts 0.00,
but it can be increased or decreased in SELECT.
•
To shut down the count: If count needs be shut down, push P key for five seconds
until no figures on the panel, meanwhile LED 1 will show green light.
•
If set value need be reset during counting, push for three seconds.
ASG, Division of Jergens, Inc.
S. Waterloo Road | Cleveland, OH
15700
44110-3898
| Phone: (
| Fax: (
| Email: [email protected] | Web: www.asg-jergens.com | Revision Date: 01/03/18
888) 486-6163
216) 481-4519
Counting Set-Up Instructions (Continued)
•
Simulated-learning: While electric screwdriver is not used, push S key and then
push P key to enter simulated-learning procedure; SL(S)===SC(S)===At(S)===
Test Data===(P)
1. Show SL (Screw List), select UP/DOWN to change number and then push S
(confirm)
2. Show SC (counting number), select UP/DOWN to change number and then push S
(confirm)
3. Show At (automatic zero), UP/DOWN to change value; then push P (confirm)
4. Enter simulated-learning (LED 1 will keep flash)
•
LED light will flash in simulated-learning. Push P key to record value after
simulated –learning.
•
UP and P key can set up waiting time.
•
Push R key to restore to factory settings.
General Execution of Pre-Set Program
•
If the screwdriver stop time is in the dotted line,
it is normal fastening. OK will be shown.
•
If the screwdriver stop time is before Lt or over
Ht stop is before Ht or over Lt, it is NG.
7