ASG PS-110 Manuel opérationnel - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel opérationnel pour {nom_de_la_catégorie} ASG PS-110. ASG PS-110 2 pages.

PS-55, PS-55C, PS-110
Power Supply Operational Manual
Front View of PS-55C
The PS-55 C is a smaller lighter power supply enclosed in a plastic case.
It has a lower output which is why it can only be used properly with
the smaller lighter torque drivers.
Front View of PS-55 and PS-110
The ON / OFF switch will illuminate when the switch is turned to the ON position. The HIGH/
LOW switch will change the DC output voltage from 30 VDC to 20VDC. The PS-110 can
power 2 drivers at the same time. NOTE: while the PS-110 unit can power two screwdrivers
simultaneously both drivers will operate at the same speed setting as determined by the
position of the HIGH/LOW switch.
CE Approval
The PS-55 and PS-110 carry the CE approval. The PS-55C does not, but is double insulated for
electrical safety and uses the same PC board assembly as the PS-55. The PS-55C does provide a
ground path through the 3rd pin on the plug.
ASG, Division of Jergens, Inc.
S. Waterloo Road | Cleveland, OH
15700
44110-3898
| Phone: (
| Fax: (
| Email: [email protected] | Web: www.asg-jergens.com
888) 486-6163
216) 481-4519
Rear View of PS-55 and PS-110
The PS-55 can operate either on 110-115 VAC or
220-230 VAC by selecting the desired voltage on
the slide switch located on the back of the units.
NOTE: 220 VAC option not available on PS-110.
Only the PS-55 is designed to connect to the STC-02
Screw Counter, ASG # 65646.
Optional cable, #65705 is available to connect the
PS-55 to a PLC or other equipment to provide a
momentary dry contact / relay closure signal when
the clutch shuts off.
Cord, Fuse, Circuit Breaker
The PS-55 and PS-110 all have a detachable IEC style
AC cord. The AC cord supplied with the units have the
correct style plug for operating in the US. If you are
using the unit on 220-230 VAC, or outside the US where
a different style connector is needed, these can be
acquired locally.
All units have an internal circuit breaker protecting the
DC output. If the breaker opens, turn the power off and
wait a few minutes to allow the circuit breaker to reset.
If the breaker is continually opening it could mean
you have a problem with the tool or the tool power
cord, the power supply or have selected the wrong
screwdriver or power supply for the application. Contact ASG.
The AC FUSE on the PS-55 and PS-110 is located in the IEC connector on the back of the
units along with a spare fuse. The spare fuse is located in the rear "pocket" of the fuse
holder. The part # for the replacement fuse is # 720318, or use a GMA-2R Bussman 2
Amp fuse or equivalent. NOTE: The PS-55C has a hard wired cord and can be operated on
110-115 VAC ONLY. The PS-55C AC FUSE is inside the case and is not recommended to be
replaced by the user.