6.4 EDID Commander

(1) This unit uses an EDID Management application which allows the user to
copy the EDID from an attached display, edit an existing EDID file stored
on the PC or create a basic EDID from scratch. The EDID can then be
uploaded to the unit for use.
(2) Please obtain the EDID Management software from your authorized
dealer and save it in a directory where you can easily find it.
(3) Before connecting the unit to your PC, please install the appropriate
Virtual COM Port Driver depending on your Windows version. Next,
install the EDID Management software.
(4) After the installation has successfully completed, an icon for it will appear
on the windows desktop. Launch the software by double-clicking on the
icon and the EDID Management device detection window will open up on
your screen.
(5) After launching the software, power the unit on and then connect it to the
PC/laptop using a USB cable. Click on the "
any detected units will be displayed in the list. Clicking on a detected unit
will open the EDID Commander window.

6.4.1 EDID Controller Tab

• Mode Select: The currently selected EDID is displayed here.
- The "User 1" EDID corresponds to the "Bitstream" setting on the front of
the unit. The "User 2" EDID corresponds to the "LPCM 7.1" setting on
the front of the unit. Both of these EDIDs are user-replaceable.
- To return them to their original values, please perform a factory reset on
the unit.