6.7 RS-232 and Telnet Commands

Command
A1~A8
B1~B8
C1~C8
D1~D8
E1~E8
F1~F8
G1~G8
H1~H8
ABCE...1~ABCD...8
SETIP <IP><SubNet><GW>
RSTIP
IPCONFIG
P0
P1
I1~I8
ST
RS
EM
?
QUIT
Note: 1. Any commands will not be executed unless followed by a
carriage return. Commands are case-insensitive.
2. When telnet is idle for 10min it will be off-line automatically.
3. EDID TV will always follow output port 1's EDID regardless on
the output change.
4. EDID setting switching will execute immediately.
Description
Switch Output A to 1~8
Switch Output B to 1~8
Switch Output C to 1~8
Switch Output D to 1~8
Switch Output E to 1~8
Switch Output F to 1~8
Switch Output G to 1~8
Switch Output H to 1~8
Switch Output ABCD... to 1~8 at the
same time
Setting IP. SubNet.GateWay<Static IP>
IP confi guration was reset to factory
defaults<DHCP>
Display the current IP confi g
Power Off
Power On
Switch all the output to 1~8
Display the current matrix state and
fi rmware version
System Reset to H8
Setting EDID MODE. 1-STD 2-TV.
Display all available commands
Exit (Telnet only)