Parcourez en ligne ou téléchargez le pdf Manuel technique de l'utilisateur pour {nom_de_la_catégorie} DOL 94-10. DOL 94-10 13 pages. Bird scale
2 Product survey
2.1 Accessories
3 Mounting Guide
1. Place the scale on the floor and check that it is in a stable position:
– where there is great movement activity, typically between water and feed lines.
– approx. 1/3 down in the house and where the scale can be seen from the entrance of the livestock
house.
– so the cable can easily be led through the litter to the wall, post or ceiling.
– so the birds cannot fly against the cable or peck the cable into pieces.
2. Connect the scale to the production controller.
DOL 94-10 is a precision product and thus requires careful handling.
Do not expose the scale to impacts or loads exceeding 10 kg. Do not step on the scale.
Permanent damage to the load cell is a risk if it is dropped.
DOL 94-10
130412 DOL 94-10 platform scale
Is used for weighing of broilers and breeders.
Supplied with 3 m cable.
Capacity: 10 kg
Supply voltage: 11 – 30 V DC
Output signal: 0 kg = 0.5 V / 10 kg = 10.00 V.
130418 DOL 94-10 Platform scale with plug
Is used for weighing of broilers and breeders.
Supplied with 3 m cable with plug.
Capacity: 10 kg
Supply voltage: 11 – 30 V DC
Output signal: 0 kg = 0.5 V / 10 kg = 10.00 V.
130961 M12x1 circular connection plug
Is used if DOL 94-10 cable needs to be extended.
Consists of:
– Cable plug four-pole female
– Cable plug four-pole male
– Dust cap 693 female plug
– Dust cap 693 male plug
www.dol-sensors.com
Technical User Guide
3