dol sensors iDOL 65 Manuel technique de l'utilisateur - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel technique de l'utilisateur pour {nom_de_la_catégorie} dol sensors iDOL 65. dol sensors iDOL 65 8 pages.
Également pour dol sensors iDOL 65 : Manuel (12 pages), Manuel technique de l'utilisateur (4 pages)

1 Introduction
This guide covers the installation, mounting, electrical installation and setup of the iDOL 65 Camera. The man-
ual provides the user, installer and electrician with the basic knowledge on how to mount and connect the iDOL
65 to the DOL Omni Cloud.
The electrical installation section is intended primarily for electricians commissioning and servicing the system.
Note that the iDOL 65 may only be opened for service and troubleshooting with the power supply connected by
qualified personnel.
How to set up the cloud and how the installer logs in as 'Configurator' is described in the
Omni.
Important: Before mounting the iDOL 65 in the house it is important that the customers account in the
Omni cloud is prepared, also that the placement of the iDOL 65 in the house is defined (FarmLayout).
It is also important that the installer is created as 'Configurator' in the Omni cloud and has already been
logged into his account on his mobile phone via dol Omni WebUI.

2 Product description

The iDOL 65 Camera measures the weight of finishers. The iDOL 65 uses a camera to estimate the weight
based on the size of the pig, i.e. height, width and length, etc.
The weight data is automatically uploaded to the DOL Omni cloud and can be viewed either in an internet
browser on the DOL Omni web-page or through any supported farm management systems.
3 Setup
The full process for unboxing the iDOL 65 to fully operational is described in steps and later elaborated in the
individual sections.
• Make sure that the pen where the iDOL 65 is installed is empty until the camera is ready for use.
• Unbox and install the iDOL 65 as described in this manual This includes mounting, electrical installation
and registration of location
• Install local network in the livestock house and connect in to the Internet/WAN
• Register the location of the iDOL 65 by means of the DOL Omni WebUI, see the section Registration of lo-
cation and calibration of camera [} 5]
• Calibrate the camera. Note that to complete the calibration, the camera must be clean
• Led pigs into the pen and the system is fully operational
Make sure to read the full guide before you start mounting the iDOL 65.
4 Mounting
The iDOL 65 must be mounted above the feed dispenser as shown in Figure 1. It is important that the camera
is hung horizontally to enable calibration.
No.:
Description:
1
The box front must be facing the pen floor. Maximum angle compared to
vertical (parallel to the floor)
2
Height above the floor (measured from the front of the box)
3
Distance from pen wall
4
Displacement compared to center of feed dispenser
5
The largest side of the box must be roughly parallel to the side wall con-
taining the feed dispenser. Maximum angle between these two
2
www.dol-sensors.com
Technical User Guide
User Guide for DOL
Value:
< +/- 4°
2.2-2.4m
0.6-0.8m
+/- 0.5 m
+/- 15°
iDOL 65 Camera