9. TROUBLESHOOTING
9.2 NO LIQUID COMES OUT – CAPSULE / INJECTOR BLOCKED?
6
Remove capsule holder. Push injector tool overinjector.
9
Put injector onto injector tool.
7
Removeinjectoronly on coldmachine! Turn injector tool
anti-clockwise. Remove injector. Donot leave injectorunat-
tended! Keep injectorout ofreach ofchildren!
10
Insertinjector from below into opening ofmachine. Support
injectorwith hand. Rotate injector clockwise until it fits. Fol-
low instructions in 8. "Descaling at least every 3-4 months"
onpage 14.
17
8
Insertcleaning needle into injector to unclogit. Ifnot pos-
sible, prepare a descaling solution with one descaler and
0.5 liter drinking water. Put injector in descaling solution.