Cypress EZ-PD CY4533 Manuel - Page 16

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Cypress EZ-PD CY4533. Cypress EZ-PD CY4533 20 pages. Barrel connector replacement (bcr) evaluation kit

Cypress EZ-PD CY4533 Manuel
Table 3-1. VBUS_MAX Values corresponding to SW1 Rotary Switch Positions
SW1 Switch Position
1
2
3
4
5
Note 1: Newer USB Type-C power adapters may not provide 12V. In that case, you will see 9V instead at SW1 position 3.
Note 2: Use 45W or higher wattage USB Type-C power adapters to get higher voltages (15V, 20V).
To run the demo, connect the barrel plug to the device. Then, connect a USB Type-C cable to the power adapter (or Power
Bank) and to the CY4533 EVK.
The device will now be powered by the USB Type-C power adapter (or Power Bank).
illustrate the setup.
CY4533 EZ-PD™ BCR Evaluation Kit Guide, Document Number: 002-25263 Rev. *B
Max VBUS Requested (V)
5
9
12
15
20
Figure 3-1. CY4533 EVK Connected with Barrel Plug Cable
DC_OUT Voltage (V)
Minimum Current Requested (mA)
5
9
[1]
12
[2]
15
[2]
20
Kit Operation
900
900
900
900
900
Figure 3-1
and Figure 3-2
16