Ashly Protea NE8250 Manuel d'utilisation - Page 8

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Ashly Protea NE8250. Ashly Protea NE8250 16 pages. Network enabled multi-channel power amplifiers
Également pour Ashly Protea NE8250 : Manuel d'utilisation (16 pages), Spécifications (2 pages), Fiche technique (2 pages), Manuel d'utilisation (16 pages), Manuel d'utilisation (16 pages), Manuel d'instruction (8 pages), Manuel d'utilisation (20 pages), Manuel d'utilisation (20 pages)

Ashly Protea NE8250 Manuel d'utilisation
Operating Manual - NE Multi Channel Power Amplifiers
4. REMOTE AMPLIFIER CONTROL
ON/OFF/Remote Standby
The NE multichannel amplifiers have three possible states, OFF, ON, and STANDBY, each with a status LED on
the front panel. Control for these three states is managed by the following:
1) Power Switch - When the power switch is turned off the amplifier is completely off, UNLESS the power switch
has been disabled from within Protea
the power switch has been disabled from software, the front panel DISABLE LED will be lit. Even if the AC power is
removed, the amplifier's internal memory will maintain the <power switch disabled> status until changed again from
ne
software. Performing a factory reset will clear and restore all internal amplifier memory to factory settings.
Protea
2) Remote Standby Contact Closure - When these two euroblock pins on the back of the amplifier are wired to
a switch and connected, the amp will go into Standby mode, whereby the amp is active but not fully powered up. For
Remote Standby to work, the power switch must be turned on OR be disabled through Protea
3) Protea
ne
Software On/Standby - On/Standby in the Protea
same as the hardware based Remote Standby Contact Closure on the back panel. Clicking on STANDBY places the amp
in standby mode. The On/Standby in software does not override the hardware Remote Standby, they both remian active.
4) Protea
Software Power Switch Enable/Disable - Use this software feature to disallow use of the front panel
ne
power switch. If the power switch has been disabled from software, the front panel DISABLE LED will light. The
power switch will remain inactive until enabled again from software, even if the amp is removed from power.

Preset Recall

The four contact closure connections on the back panel euroblock allow for four different amplifier stored presets
to be loaded at the instant a remote switch is closed. Presets are configured from Protea
settings, mute status, polarity, as well as the full set of DSP functions if the amp has the DSP option installed.
The NE amplifier will store up to 35 named internal presets, each preset storing control data for all channels and
audio functions. While working in Protea
using <Preset Options/Save Preset To Protea>, or saved to the PC using <Preset Options/Save To Disk>. Sub Presets
(collections of DSP parameters individually selected from software) are saved in a similar fashion. Individual preset
files use the extension (*.pmc).
The only way to load presets to an amplifier is by using Protea
the amplifier itself, through the use of contact closures, or with a WR-5 wall-mounted remote control. Contact closures
can load presets 1-4 from the amplifier memory using switches wired to the rear panel contact closure euroblock connec-
tor.
Caution: A new preset may have dramatically different settings capable of damaging sound system components,
so be careful not to recall the wrong preset while the system is on.
Data Control
The Data Control euroblock connector on the back of the amplifier is used for the Ashly WR-5 programmable zone
controller and Ashly RD-8C remote level controller. The Data Control interface provides data and phantom power for
these devices in remote installations, using four conductor wire.
8
ne
software, in which case the power switch on the amplifier has no effect at all. If
ne
software, changes to an individual preset can be saved to the amplifier
ne
ne
PE multichannel amp software functions the
ne
software and can include gain
ne
software to recall files saved on either the PC or
software.