4. If you have problems, please refer to the more detailed sections and to
the troubleshooting
guide in this manual. Q
MECHANICAL INSTALLATION
The CL-50E and CL-52E Compressor/Limiters
mount in a standard 19
inch equipment rack. The mounting
screw threads vary with different rack
manufacturers and you should refer to your rack instructions for proper
hardware. An oval head or flat head screw with a plastic countersink washer
is preferred to protect the finish of the compressor/limiter under the screw.
The CL-100 is housed in an industry standard half-rack enclosure which
provides a variety of mounting options. It can be used free-standing, in a half-
rack-sized enclosure, mounted in a vertical 19 inch adaptor with up to eight
other half-rack products, or side by side with another half-rack product in a
standard 19-inch
rack. Mounting accessories
are available from Ashly to
accomplish this.
Your Ashly compressor/limiter
is housed in a rugged steel case and will
tolerate moderate abuse. However, for road systems which may be dropped
or otherwise subjected to extreme forces, we recommend some rear support
for the chassis to prevent bending the front panel when these forces occur. Q
WIRING
The CL-50E and CL-52E Compressor/Limiter
should be connected to a
3-wire grounded outlet supplying 120 Volts, 50-60 Hz. Power consumption is
12 watts. The CL-100 uses a standard RAP-6 remote AC power supply.
The INPUT is a 10k ohm active balanced type on a standard stereo
phone plug that will accept levels of up to +20 dBV. The (+) or in-phase
connection is on the tip and the (-) or out-of-phase connection is on the ring.
To use the input as a common unbalanced type, simply use a mono phone
plug in the usual way.
The OUTPUT connection
is a standard 1/4" phone jack and mates with a
standard phone plug such as a Switchcraft 280. Output impedance is 200