ASI SAFE-Dri 0198-MH Manuel du propriétaire - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel du propriétaire pour {nom_de_la_catégorie} ASI SAFE-Dri 0198-MH. ASI SAFE-Dri 0198-MH 2 pages. Mental health approved high-speed hand dryer

SAFE-Dri™ - HIGH SPEED ANTI-LIGATURE HAND DRYER (PAGE 2 OF 2)
INSTALLATION
Mount unit cabinet in wall recess with four (4) № 10 [M5] screws (not supplied) into suitably prepared mountings
(by others) or other suitable mounting hardware (by others) to suit wall conditions. For masonry walls use
expansion bolts or anchors for 1/4" [M6] screws. See unit diagram for electrical service cable rough-in location.
Electric service of 100-240VAC 20A 50/60 Hz (provided by others) is brought to RWO at location for dryer
indicated on diagram above and is hooked up (by others) in accordance with schematic and Owner's Manual
provided with unit. Electrical service is supplied and connected (by others) prior to installing cover. Cover is
secured to cabinet with
ANSI A-117.1 and 2010 ADA Accessibility Standards install unit with top of dryer hand chamber 48" [1219]
maximum above finished floor (MAX AFF) if clear floor reach access is provided or 46" [1168] MAX AFF if side
reach access over an obstruction (e.g. vanity) with reach depth greater than 10" [254] and less than 25" [635] is
only provided or 44" [1118] MAX AFF if forward reach over an obstruction (e.g. commode) with reach depth
greater than 20" [508] and less than 25" [635] is only provided. For general utility install unit so that top of dryer
hand chamber is 44" to 50" [1118 to 1270] AFF. Note that top of RWO is 9/32" [7] below top of unit.
installation of two or more dryers, dryers should be no closer than 24" [610] on center. See OM and Template MT
& IG supplied with unit.
RWO required is 12-1/4" W x 15-3/16" H x 5-1/4" D minimum [311 x 386 x 133]
OPERATION
User activates dryer by placing hands under sensor. Dryer automatically shuts off after time-out when user
removes hands from sensor zone.
MODEL
TYPE
TIMING
0198-MH-1
Hand
Automatic
0198-MH-2
MOTOR
H/P
RPM
Brush Type
Dual Ball
0.67
Bearings
AMERICAN SPECIALTIES, INC.
441 Saw Mill River Road, Yonkers, NY 10701
(914) 476.9000 • (914) 476.0688
www.americanspecialties.com
four (4) pin-hex socket flat head security screws
SUPPLY
AC VOLTS ● HERTZ (HZ)
115-120 ● 50/60
208-240 ● 50/60
FAN TYPE
AIR FLOW
Multi-Inlet
[102 m
29
Centrifugal
THIS MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES IN DESIGN OR DIMENSIONS WITHOUT FORMAL NOTICE
AMPS
(MAX)
HEATING ELEMENT
60 CFM
/h]
500 Watt with auto reset
3
230 ft/s
circuit breaker
[70 m/s]
MODEL №:
ISSUED:
REVISED:
(supplied). For compliance with ICC/
WATTS
X1000
10.4
0.84-1.0
5.2
0.84-1.0
131º F ± 5 @ 77º F
[55º C ± 2.8 @ 25ºC]
Ambient room temperature
0198-MH
6/2015
22 Feb 2016
For
COVER
Satin Finish;
Vertical Grain;
304 Stainless Steel
HEAT TEMP.