FLASH UPGRADE USER GUIDE
10. Press "Send". The file will be transferred and the status and progress can be seen in the
"Hyperterminal" status window. You will not receive visual feedback on the projected
image during flash except the indicator stating time left and the progress of the EPROM
flashing.

7. FINISHING THE FILE TRANSFER

When the END prompt is visual in Hyperterminal the flashing is finished (approx. 2min.).
1. Leave the projector running for approximately 30 seconds to prevent that the
reprogramming isn't halted. The lamp of the projector will continue to work and the fans
will continue running as in ON mode. At this time, the projector is reprogramming the
EPROM.

8. VERIFYING THE DOWNLOAD

After the download has been finished verification needs to be made that it has ended
successfully and to stop the projector from running the power cord must be pulled out.
1. Reinstall the power cord and start the unit using normal procedures.
2. Disconnect all sources and verify whether the new SW was successfully installed or not
by checking the ADVANCED /SERVICE / INFO dialog-box in the projector menu. If the
new SW/HW number doesn't appear as intended, please check the following :
Does the flashed file have the correct .BIN format?
Was the correct protocol used during the download?
Was the correct communication settings being used?
3. It is possible to reinsert the initial SW/HW by flashing with the original firmware revision
for the projector. This is available through our web page under "MLS resources |
Firmware.." .
4. If the unit does not start, the download has failed and the EPROM(s) must be replaced
physically.