Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation et d'installation pour {nom_de_la_catégorie} AERMEC Omnia UL 16 N. AERMEC Omnia UL 16 N 9 pages. Fan coil unit with inverter brushless motor eech for floor installation with electronic thermostat and purifier plasmacluster, for residential use

AERMEC Omnia UL 16 N Manuel d'utilisation et d'installation
USE OMNIA ULI_PC
COMMANDS:
Ventilation is only allowed when the fins are open; if necessary, open them manu-
ally. Closing the fins switches off ventilation although the electronic thermostat remains
active and continually records ambient data to ensure a prompt restart if the fins are
opened again. The "PLASMACLUSTER" purifier is automatically activated when the ven-
tilation starts up.
STARTING
OFF
The fan coil is switched off.
It may however start again in Heat mode (anti-freeze function) if the room temperature
falls below 7°C and the water temperature is suitable; in this case the red LED flashes.
To start the fan coil, turn the knob towards the functioning mode required in the AUTO
position or in one of the three ventilation speeds.
SELECTING THE SPEED
AUTO The thermostat maintains the set temperature by changing the fan speed in
Automatic Mode in accordance with the room temperature and the set temperature.
V1 In this position, the minimum ventilation speed stays active regardless of ther-
mostat requests.
V2 In this position, the minimum ventilation speed stays active regardless of ther-
mostat requests
V3 In this position, the minimum ventilation speed stays active regardless of ther-
mostat requests
AUX = In this position, ventilation is linked with the type of accessory connected to the
thermostat.
VENTILATION LOGIC IN AUX POSITION
SYSTEM
2-pipe system
2-Pipe System with Plasma Cluster
2-Pipe System with Bactericide lamp
LIGHT VISUALISATIONS (ULI_PC in the standard configuration)
The LED (C) changes colour to indicate the functioning mode
that is active:
RED
On indicates Heat operation
(heating).
Flashing indicates anti-freeze mode.
BLUE
On indicates Cool operation
(cooling).
FUCHSIA Flashing: Indicates that there is a permanent inverter
alarm.
14
IULIPCLJ 1201 - 6976445_00
VENTILATION
Auto
V1
V1
The LED (D) indicates a request from the electronic thermostat
for ventilation:
YELLOW On: Indicates that the thermostat has detected a
room temperature that requires ventilation to be
started; if this does not occur, it means that the
water circulating in the system has not yet reached a
suitable temperature for enabling ventilation, when
the ventilation is activated, the PLASMACLUSTER is
also activated at the same time.
Off Indicates that the fins are closed and the fan can-
not start.
If the fin is open, led (D) Off Indicates that the ther-
mostat is in stand-by (selector switch A is in position
OFF) or that the thermostat does not require the fan
to operate.
Flashing indicates a functioning fault of the ambient
probe (Emergency Mode).
-
+
+
-
DESCRIPTION
Ven la on func ons with the
thresholds of Auto mode (except in
pre-ven la on / post-ven la on)
Ven la on ac ve at minimum speed
for environment puri ca on.
Ven la on ac ve at minimum speed
for environment puri ca on.