Technical specifications:
Parameter
Charging section
Charging type
AC
Power Source
Output Voltage #1
Outlet [external]
Maximum output #1
Output Voltage #2
Outlet [external]
Maximum output #2
Output Voltage #3
Outlet [external]
Maximum output #3
Output Voltage #4
Outlet [internal]
Maximum output #4
Over current protection of
outputs
Short circuit protection of
outputs
Over temperature protection
Display
Number of battery positions
(channels)
Position type
Conversion efficiency of DC-
DC converters
Operating temperature range
Storage temperature range
Operating/Storage humidity
Dimensions
Weight
Value
4 x 16.7V/65W charging units
simultaneous
110V to 240V , 50/60Hz
Uninterruptable by battery hot swapping
48V (selectable) +/- 3% on no load
2 x 3pin female XLR
560W (outputs from both 48V XLRs combined)
28V (selectable) +/- 5% on no load
2 x 3pin female XLR
560W (outputs from both 28V XLRs combined)
14V (always available) +/- 5% on no load
2 x 4pin female XLR
340W (outputs from both 14V XLRs combined)
5V (always available)
Twin USB socket
15W (3A) total output
Available on all outlets
Available on all outlets
Available
20 column x 4 rows backlit white characters/ blue
background
4 (1 to 4)
Hot-swappable on all 4 channels
>= 90%
0°C - 50°C (32°F - 122°F)
-20°C - 65°C (-4°F - 149°F)
5% to 90% RH
434 x 371 x 193 mm (17.09" x 14.61" x 7.60")
5.5 Kg (12.13 lbs) excluding batteries
13