d&b audiotechnik Ci90 Manuel - Page 5
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} d&b audiotechnik Ci90. d&b audiotechnik Ci90 10 pages. Flying bracket
Également pour d&b audiotechnik Ci90 : Manuel (10 pages), Instructions de montage (11 pages)
10
5
0
-5
-10
-15
-20
-25
-30
20
100
1k
Fig. 3: Frequency response correction with
HFA setting
Fig. 4: Frequency response correction of
CPL circuit
DELAY ON
REMOTE
LO IMP
ON
1
2
3 4 5 6
7
8
SPKR
HFA
CUT
Fig. 5: E-PAC Configuration for Ci60/Ci90
(E-PAC version 2)
Ci45/Ci60/Ci90 Manual
Controller settings
For acoustic adjustment the functions CUT, HFA and CPL can be
selected.
CUT circuit
Set to CUT, the Ci60/Ci90/Ci45 low frequency level is reduced. The
loudspeaker is now configured for use with the Ci-SUB, Q-SUB or d&b
C-Series subwoofers.
HFA circuit
In HFA mode (High Frequency Attenuation), the HF response of the
system is rolled off. The HFA provides a natural, balanced frequency
response when a unit is placed close to listeners in near field or delay
use.
High Frequency Attenuation begins gradually at 1 kHz, dropping by
approximately 3 dB at 10 kHz. This roll-off mimics the decline in
frequency response experienced when listening to a system from a
distance in a typically reverberant room or auditorium.
10k
20k
CPL circuit
The CPL (Coupling) circuit compensates for coupling effects between the
cabinets when building closely coupled arrays. CPL begins gradually at 1
kHz, with maximum attenuation below
250 Hz, providing a balanced frequency response when cabinets are
used in arrays of two or more. The function of the CPL circuit in the D12
amplifier is shown in the diagram opposite and can be set in dB
attenuation values between –9 and 0, or a positive CPL value which
creates an adjustable low frequency boost around 65 Hz (0 to +5 dB).
Operation with E-PAC
To drive Ci60/Ci90 or Ci45 loudspeakers the E-PAC has to be
configured to Ci60/Ci90 (CI6/CI9) mode (possible with E-PAC version 2
from serial number Z2500.000.02-01313 and E-PAC version 3) or Ci45
mode (possible with E-PAC vesrion 3).
For an E-PAC version 2, the configuration is selected by setting the
appropriate DIP switches on the rear panel.
For an E-PAC version 3, the configuration is set via the encoder in
conjunction with the LCD.
Selecting Ci60/Ci90/Ci45 mode enables one Ci60/Ci90/Ci45 cabinet
to be driven at an output power of 300 Watts. LO IMP mode allows the
E-PAC to drive two cabinets with a 6 dB reduction of input level to the
speakers.
The CUT and HFA settings are available on versions 2 and 3 and are
explained under the previous section "Operation with D12 - Controller
settings".
(9.1E)
Page 5 of 10