Recommended Maintenance
As with any marine product, proper care and regular maintenance is highly
recommended.
In order to help prevent premature failure of your ACR searchlight the following
steps are recommended:
The best preventative maintenance one can do is to ensure that the best possible care is taken
when installing the light. The biggest problem on these lights is water intrusion from the way it
is mounted, if not done well.
During the lifetime of the light, a regular, very close inspection must be made of the paint
around the base of the unit. ANY sign of lifting, flaking or 'bubbling' of the paint around the
base is a sign of water intrusion. Any sign of humidity on the inside of the glass lens of the light
is trouble.
The best time to inspect the light is early in the morning. During the day the light is heated by
the sun, all air is pushed out, at night the humid air is pulled in and the moisture builds up.
• Always try to keep the light surface clean. Build up of salt, dirt or paint cause corrosion.
• Periodically (recommend monthly) rotate and elevate your light to help extend operational life
of the motors. The URC-102 Master Controller has a built in XRCiZ feature. When this
feature is enabled, the Master Controller will automatically rotate and elevate the searchlight
once a month.
• Normal temperature fluctuations can cause condensation (condensation is any moisture on
inside of glass) to form inside body of the light. If condensation is observed, remove the
front frame and allow unit to dry.
• Whenever disassembling the searchlight, use anti-seize compound (such as Tef-gel™) on
bolts and hardware. Rejuvenate gaskets with silicon grease and replace worn or missing
phenolic and/or nylon shoulder washers.
• Forceful Manual turning of the light is discouraged due to the possibility of damage to internal
components.
• Silicon grease can be used to rejuvenate all gasket material.
• Replace worn or missing phenolic and/or nylon shoulder washers.
• If the base of the light is removed for any reason, be sure to re-install using nylon shoulder
washers in the bolt holes to help prevent the natural reaction of dissimilar metals (aluminum
& stainless steel).