Cylinder head bolt tensions
A qualified person should tighten the cylinder head bolts. Please seek professional
assistance.
Battery check
Make sure the battery acid is full. The engine uses a 12V battery. Due to numerous
starting cycles, the battery acid may be used up. Also, before filling, verify that the
battery is not damaged in any way. Add distilled water to the battery when filling.
Perform checks on the battery once a month.
Note: The battery contains sulfuric acid. Protect your eyes, shin and clothing. In case of
contact, flush thoroughly with water and get prompt medical attention. The battery emits
hydrogen gas, which can be highly explosive. Do not smoke or allow flames or sparks
near the battery, especially during charging.
Long-term storage
If you store the generator for long periods of time, the following preparations should be
taken:
1) Operate the engine for about 3 minutes and then stop.
2) Stop the engine. Drain the engine oil while the engine is still warm and fill with
fresh oil.
3) Remove the screw plug on the cylinder head cover and refill 2cc engine oil;
replace plug.
4) Recoil starting: Push the decompression lever down (non-compression position)
and hold it while you pull the recoil starter 2-3 times. (Do not start the engine.)
5) Pull the decompression lever up. Pull the recoil starter slowly. Stop when you
feel resistance. At this point, both intake/exhaust valves are closed to prevent the
engine from the rust.
6) Wipe off the oil and dirt from the engine and store in a dry place