Tenbury insert install manual 1015-3 03/12/2015 09:57 Page 3
Nominal heat output
Chimney draft required
Height
Width
Depth
Weight
Air Requirement
Flue Mass Gas Flow
2
CO @ 13% O
Mean Flue Gas Temperature
Efficiency
Log Length
Hearth Temperature
*** Please note that Building Regulations Document J advises that additional permanent air supply is
required for appliances with an output of above 5Kw.
With modern properties additional air may be required as Document J suggests that adequate air
would be a benefit.
• If design air permeability ≥5.0m³/ (h.m²) then 550mm²/kW of appliance rated output above 5kW
Or
• If design air permeability ≤5.0m³/ (h.m²) then 550mm²/kW of appliance rated output
• If in doubt, please consult your registered installer for advice.
DO NOT INSTALL IN A ROOM CONTAINING AN EXTRACTOR FAN UNLESS
THE APPLIANCE HAS BEEN CORRECTLY TESTED IN ACCORDANCE
473
Tenbury Specifications
5 kW - Wood
12Pa
550 mm (Internal Box) 588 mm (External Trim)
440 mm (Internal Box) 472 mm (External Trim)
334 mm (Recessed) 339 mm (External Trim)
60 kg
N/A ***
3.2g/s - Wood
0.23 Wood Vol%
263°C - Wood
82.9% - Wood
Up To 250 mm
152ºC
WITH BUILDING REGS DOC J
334
4.8 kW - Smokeless Fuel
5.7g/s - Smokeless Fuel
0.21 Smokeless Fuel Vol%
276°C - Smokeless Fuel
73.8% - Smokeless Fuel
396
11.5