XO-XOi-X86-DR-X86T MANUAL - RS485 Manual - v3.2

Serial port specification

Serial Port Hardware

RS-232
DB-9 Female
RS-485
Screw Terminal (4 connections)
RJ-45

Serial Port Communication Protocol

RS-485 asynchronous serial communication
Two Wire Half Duplex
9600 bps, 8 bits, 1 stop bit, no parity
no flow control

Command set specification

Command Format

All commands are in ASCII characters format except the first DEVICE ADDRESS
byte
DEVICE ADDRESS is an 8 bit hexadecimal character assigned by the 8 bit DIP
switch on this device
All commands begin with DEVICE ADDRESS and "*" (asterisk) character and end
with <CR> character (0D hexadecimal)
All commands RETURN with some feedback begin with DEVICE ADDRESS and "*"
(asterisk) character and and end with <CR> character (0D hexadecimal)
If a command produces an error or structured with incorrect syntax, the system
will return with "<ADDR>?<CR>" characters
Multiple commands require a delay of 500ms between commands

COMMAND

RETURN