AMC SMILE 16/P Panduan Memulai Cepat - Halaman 4

Jelajahi secara online atau unduh pdf Panduan Memulai Cepat untuk Sensor Keamanan AMC SMILE 16/P. AMC SMILE 16/P 4 halaman. Digital pir detector pet immune

AMC SMILE 16/P Panduan Memulai Cepat
SPECIFICHE TECNICHE / SPECIFICATIONS / SPECIFICATIONS TECHNIQUES
Alimentazione / Input Voltage / Alimentation
Consumo / Current Drain / Consommation: (Alarm/Stand-By)
Portata in lunghezza / Coverage / Portee:
Portata in larghezza / Angle / Angle de couverture
Piroelettrico / PIR / Pyroelettrique
Lente / Lens / Lentille
Durata allarme / Alarm period / Duree alarme
Compesazione termica / Thermical compesation / Compensation thermique
Antiapertura / Anti-opening / Autoprotection
Antistrisciamento / Creep zone / Detection sous le detectour
Contatto di allarme / Alarm contact / Contact d'alarme
Contatto di tamper / Tamper switch / Contatct d'auto-protection
Contatore impulsi / Event counter / Comptage d'impulsion
Temperatura di esercizio / Operating temperature / Temperature de fonction-
nement
Temperatura di stoccaggio / Storage temperature / Temperature de stockage
RFI Protezione / Protection / Protection
Led WALK TEST
WALK TEST Ingresso / Input:/ entreé
Cover / Housing / Boiter
Accessori / Accessories / Accessoires
Dimensioni / Dimensions
*: Non coperto da omologazione .
Meets the requirements:
Conforme ai requisiti:
R&TTE 99/5/CE
EN 50131-2-2: 2008
EN 50131-2-2 Grade 2
EN 50131-2-2 Class 2
CEI 79-2: I° Level
Prodotto conforme alla Direttiva 99/5/CE. La dichiarazione di conformità è disponibile presso la nostra sede.
Tutti i ns. prodotti sono conformi ai requisiti richiesti dalla norma CEI 79-2 2°ed. 1998 + Ab 2000.
L'installazione deve essere eseguita a regola d'arte da personale specializzato.
Il produttore declina ogni responsabilità nel caso in cui il prodotto venga manomesso da persone non autorizzate.
Si raccomanda di verificare il corretto funzionamento del sistema d'allarme almeno una volta al mese, tuttavia un sistema di allarme elettronico
affidabile non evita intrusioni, rapine, incendi o altro, ma si limita a diminuire il rischio che tali situazioni si verifichino.
This product comply the 99/5/CE directive. The declaration of conformity is available at our offices.
Our products/systems comply with the essential requirements of EEC directives.
Installation must be carried out following the local installation norms by qualified personnel.
The manufacturer refuses any responsibility when changes or unauthorized repairs are made to the product/system.
It is recommended to test the operation of the alarm product/system at least once a month. Despite frequent testing and due to, but not limited to,
any or all of the following: tampering, electrical or communication disruption or improper use, it is possible for the product/system to fail to prevent
burglary, rubbery, fire or otherwise. A properly installed and maintained alarm system can only reduce the risk that this happens.
Produit conforme à la Directive 99/5/CE. La déclaration de conformité est disponible chez notre société.
Tous nos produits sont conformes aux requises prévu par la norme CEI 79-2°ed. 1998 + Ab 2000.
L'installation doit ètre effectuée dans les règles de l'art par un installateur qualifié.
AMC Elettronica S.r.l. décline toute responsabilité en cas d'utilisation des produits par des personnes non habilitées.
Il est recommandé de vérifier le bon fonctionnement du système d'alarme au moins une fois par mois.
Un système d'alarme électronique n'exclut pas le risque d'intrusion, de vol, d'incendie mais limite et diminue fortement celui-ci
www.amcelettronica.com
SMILE 16 Digital Pir Detector
3
9 to 15 Vdc
(7.6 mA/10 mA) @ 13.8 Vdc
from 3 to 18 m
90°
2 elementi / 2 elements
29 patterns on 5 levels
4 sec.
max 100 mA - 40 Vdc - 16 Ω
max 40 mA - 30 Vdc
2 count. for 5 sec. (selectable)
from -10 °C to +55 °C
from -20 °C to +60 °C
10 V / m (20 MHz - 2000 MHz)
ABS
snodo orientabile / Swivel bracket /
Rotule orientable*
110 x 60 x 46 mm
Installation Instructions v1.1