ACR STOVES Astwood II Panduan Teknis - Halaman 3

Jelajahi secara online atau unduh pdf Panduan Teknis untuk Kompor kayu ACR STOVES Astwood II. ACR STOVES Astwood II 17 halaman. Multifuel stove

Nominal heat output
Chimney draft required
Height
Width
Depth
Weight
Air Requirement
Flue Mass Gas Flow
2
CO @ 13% O
Mean Flue Gas Temperature
Efficiency
Mean CnHm @13%O2
Mean NOx @13%O2
DIN Plus Dust @13%O2
Log Length
*** Please note that Building Regulations Document J advises that additional permanent air supply is
required for appliances with an output of above 5Kw.
With modern properties additional air may be required as Document J suggests that adequate air
would be a benefit.
• If design air permeability ≥5.0m³/ (h.m²) then 550mm²/kW of appliance rated output above 5kW
Or
• If design air permeability ≤5.0m³/ (h.m²) then 550mm²/kW of appliance rated output
• If in doubt, please consult your registered installer for advice.
If installing into a room containing an extractor fan, please ensure that the relevant tests are
carried out according to Document J of the building regulations.
Removable 80mm direct air collar at 120mm from hearth level.
Astwood II Specifications
5 kW - Wood
12Pa Min. Start up
596 mm
542 mm
420 mm
95 kg
N/A ***
4.4 g/s - Wood
0.09 Wood vol %
253°C - Wood
80.8% - Wood
Wood - 51Nmg/M3
Wood -94Nmg/M3
Wood -31Nmg/M3
Up To 420 mm
542
500
5 kW - Maxibrite
3.1 g/s - Maxibrite
0.11 Maxibrite vol%
245°C - Maxibrite
82% - Maxibrite
Maxibrite - 21Nmg/M3
Maxibrite - 83Nmg/M3
Maxibrite -6Nmg/M3
390
330
355
420