AME Fasy-Flate 24868 Manual - Halaman 8
Jelajahi secara online atau unduh pdf Manual untuk Alat Listrik AME Fasy-Flate 24868. AME Fasy-Flate 24868 12 halaman. Digital automatic tire inflator (portable)
Troubleshooting
PROBLEM
Air leak
The inflator works,
but no air is flowing
No display
Inflation does not start,
although the pressure is set
and the hose is connected
with tire
Err1
Err2
Err3
Err4
Err5
Err8
8
8
POSSIBLE CAUSE
Leak in the connection
Obstruction in filters or in
air system
Flat battery
Air hose improperly connected
Tire pressure is below
3 p.s.i.
Pressure sensor broken
Unstable pressure,
faulty hose connector
Connected tire pressure is
too high 180 p.s.i.
Wrong connections at air inlet
and outlet
Low battery
Air supply lower than set
inflate pressure
SOLUTION
Check the Connection
Clean the filters and
check the air source
Recharge battery
Check the hose
connection, make sure
that no air leaks
Manual inflation
Power off, change
pressure sensor
Replace hose connector or
re-connect hose to the tire
Stop inflating this tire
Refer to wiring diagram and
connect magnetic valve
accordingly
Plug in unit to recharge the
battery
Stop inflating this tire