Environmental
•
Operating Temperature: 0°C to 32°C
•
Storage Temperature: 0°C to 65°C
•
Humidity:
5% to 90% RH, Non-Condensing, for temperatures 0°C to 40°C
o
5% to 60% RH, Non-Condensing, for temperatures 0°C to 65°C
o
•
Maximum Altitude of Operation: 3000m
•
Maximum decibel level: 73 dB(A)
Electrical
•
Motor Type: BLDC
Motor Phase Voltage: 160 Volts Pulse DC @ Controller Supply Voltage of
o
120 RMS, or 320 Volts Pulse DC @ Controller Supply Voltage of 230 RMS
•
Duty Cycle: The Nutrunner tools are intended for intermittent operation with recommended
maximum duty cycles not to exceed 33%. Note: actual maximum duty cycles are dependant
upon several factors including: Ambient Temperature, Tool selection, Joint conditions,
Fastening-parameter programming, and different applications and strategies. For optimum
duty cycle determination, please contact your AcraDyne sales representative.
Physical
•
1.5 lbs/.68 kg - 2.6 lbs/1.18 kg
Performance
•
Torque Range: 3 - 22 NM
•
Speed Range: 560 - 2625 RPM
Specifications