Aktakom ATH-2231 Panduan Pengguna - Halaman 15

Jelajahi secara online atau unduh pdf Panduan Pengguna untuk Catu Daya Aktakom ATH-2231. Aktakom ATH-2231 15 halaman.

Problem
The power supply cannot
start up (NO DISPLAY)
While operating in the CV
mode, the voltage suddenly
drop
down and the CC
indicator turns
The power supply output
unstable.
If the above solution cannot solve the problem, please contact the local dealer, distributor or the manufacturer
listed at the back.

7. TROUBLESHOOTNG

Solution
1. Ensure the power source or power cord is working properly
2. Check the fuse .if the fuse broken, disconnect from the power source then
replace with identical rated fuse.
This power supply is current protected. The desired current range is under the
circuit gain; therefore, the power supply is switched to CC mode, Adjust the
current knob clockwise to increase the current range.
1. The power supply needs at least 30minutes to warm up and reach the
specification.
2. The power source (voltage)is under the minimum requirement.
15