Directions for use:
1.) First, insert the supplied drain hose over the water outlet nozzle. Make sure that the
hose is properly and firmly inserted on the water outlet nozzle.
Then connect the connection socket of the pump with the connection plug of the
power cable. Take special care here that everything is firmly connected and that this
cable connection is outside the water tank and the dehumidifier !
2.) Place and fix the pump on the bottom of the water tank. Make sure that the pump is
placed straight and stable. Use the suction knobs attached to the device for this
purpose.
3.) Now guide the drain hose through the outlet provided for this purpose on the
dehumidifier (e.g. plug to the hose connection) and guide the end of the hose to a
water drain (sink, drain, WC, etc.). Please ensure that the pump can only pump
upwards a maximum of 3 meters.
4.) Now also lead the power cable of the pump through the outlet provided for this
purpose on the dehumidifier and connect the mains plug to your socket. Your
condensation pump is now ready for use.
As soon as the water level in the water tank reaches
the sensor on the condensation pump, the pump will automatically turn on and pump
the water out of the tank.
As soon as the water level in the water tank drops again, the pumping process is
stopped by the sensor.
Technical data:
Model name:
Voltage:
Max. Power consumption:
Length of the hose:
Tube diameter:
Protection class:
Max. Head:
Max. Flow rate:
Dimension (H/W/D):
Weight:
For the technical data are subject to deviations !!!
WDH-KP40
100 - 240 V ~ 50/60Hz - 12V
approx. 8 W
3 m
1 cm
IPX8
3 m
450 L/h
60 x 50 x 70 mm
0,2 kg
Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany
www.AKTOBIS.de