14
LIFT ARM
FIRST
IMPORTANT: Always clear
sand and rust from system.
• Make sure water supply is off.
Remove valve TOP by lifting
arm and rotating top and arm
1/8 turn counterclockwise,
pressing down slightly on cap.
Always use quality Fluidmaster repair parts when maintaining your Fluidmaster products. Fluidmaster
shall not be responsible or liable for any damages caused by products used with Fluidmaster valves that
were not manufactured by Fluidmaster, Inc.
Repair parts are determined by toilet tank number which can be found marked inside tank.
NOTE: "XXX" represents color or trim finish options. Specify when ordering.
PART NO.
738995-XXX0A
738997-XXX0A
738835-XXX0A
738837-XXX0A
034783-XXX0A
738565-424-0070A
7301111-0070A
3174.002-0070A
738985-0070A
738570-1010A
738756-0070A
735128-400-XXX
735109-400-XXX
735113-400-XXX
072989-0070A
PROBLEM
a. Water supply valve closed.
Does not flush
b. Supply line blocked.
c. Flush valve chain too loose or disconnected.
d. Sand or debris lodged in water control.
a. Bowl water level too low.
Poor or sluggish flush
b. Supply valve partly closed.
c. Partially clogged trapway and/or drain pipe and/or vent.
d. Supply pressure too low.
e. Flush valve chain too tight, holding flush valve open.
a. Poor supply line connection.
Toilet leaks
b. Poor bowl to tank/floor connection.
a. Flush valve seal leaking or deformed.
Toilet does not shut off
b. Sand or debris lodged in water control.
In the United States:
American Standard Brands
Piscataway, New Jersey 08855
Attention: Director of Customer Care
For residents of the United States, warranty
information may also be obtained by calling
the following toll free number: (800) 442-1902
www.americanstandard.com
• While holding a
container over the
uncapped VALVE to
prevent splashing, turn
water supply on and
off a few times. Leave
water supply off.
REPAIR PARTS LIST
DESCRIPTION
®
Champion
4 LH Trip Lever
Champion
®
4 RH Trip Lever
Champion
®
4 LH Trip Lever
®
Champion
4 LH Trip Lever
Bolt Cap Kit (Incl. 2 Covers & Washers)
Champion
®
4 Fluidmaster 400a Valve
®
Champion
4 Flush Valve Seal Kit
Champion
®
4 Flush Valve Assembly
Champion
®
4 Clevis Pin Assembly
®
Champion
4 PVC Refill Tube
Champion
®
4 Tank To Bowl Coupling Kit #241
®
Champion
4 Tank Cover
®
Champion
4 Tank Cover
Champion
®
4 Tank Cover
Clip for Refill Tube
POSSIBLE CAUSE
P.O. Box 6820
• Replace TOP by engaging
lugs and rotating 1/8 turn
clockwise. MAKE CERTAIN
TIP IS TURNED TO THE
LOCKED POSITION. VALVE
MAY NOT TURN ON IF TOP
IS NOT FULLY TURNED TO
THE LOCKED POSITION.
TROUBLESHOOTING GUIDE
a. Open valve and allow water to fill tank.
b. Shut off water supply, disconnect supply line and inspect all
gaskets and washers. Reassemble. Also, see Fluidmaster
maintenance. (see Step 14)
c. Readjust chain length as required.
d. Shut off water supply. Remove cap and clean as per Step 14.
a. Check that refill tube is connected to water control and
inserted into tank overflow without being kinked or damaged.
(see Step 13a)
b. Open supply valve fully. Be sure that proper supply tube size
is used.
c. Remove obstruction. Consult a plumber if necessary.
d. Normal supply pressure must be at least 20 psi.
e. Readjust chain length as needed. Review Step 10.
a. Review Step 9 of installation procedure.
b. Review Step 4 through 7 of installation procedure.
a. Clean debris from seal surface. Replace flush valve seal as
needed. (see Step 13)
b. Shut off water supply. Remove cap and clean as per Step 14.
In Canada:
AS Canada, ULC
5900 Avebury Rd.
Mississauga, Ontario
Canada L5R 3M3
Toll Free: (800) 387-0369
www.americanstandard.ca
- 5 -
TROUBLESHOOTING
IF FILL VALVE SHUTS OFF BUT CONTINUES TO
LEAK SLOWLY, repeat Step 14.
IF FILL VALVE TURNS OFF AND ON DURING
PERIODS OF NON-USE, it is a signal you are
wasting water because:
• The end of the refill tube is inserted into overflow
pipe, below water level in tank. Attach refill tube to
overflow pipe using "S" clip provided.
• The flush valve is leaking because it's worn, dirty
or misaligned.
IF FILL VALVE WON'T TURN ON OR SHUT OFF
or REFILL OF TANK WATER IS SLOW after valve
has been in use for some time, Fluidmaster Model
242 Replacement Seal may be needed.
Go to our website at www.fluidmaster.com for
more solutions to toilet problems.
For troubleshooting information please contact:
30800 Rancho Viejo Road
San Juan Capistrano, CA 92675
(949) 728-2000 (800) 631-2011
www.fluidmaster.com
© 2001 Fluidmaster, Inc.
® Registered trademark of Fluidmaster, Inc.
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
CORRECTIVE ACTION
In Mexico:
American Standard B&K Mexico
S. de R.L. de C.V.
Via Morelos #330
Col. Santa Clara
Ecatepec 55540 Edo. Mexico
Toll Free: 01-800-839-1200
www.americanstandard.com.mx
730529 -10 0 Rev. U
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔