Barmesa Pumps 62071047 Panduan Pemasangan, Pengoperasian & Pemeliharaan - Halaman 11
Jelajahi secara online atau unduh pdf Panduan Pemasangan, Pengoperasian & Pemeliharaan untuk Pompa Air Barmesa Pumps 62071047. Barmesa Pumps 62071047 16 halaman.
![Barmesa Pumps 62071047 Panduan Pemasangan, Pengoperasian & Pemeliharaan](/uploads/products/server2/1093692/1093692.jpg)
Table 1
Equivalent length in meters of straight pipe and valve connections for calculating friction.
PART
barmesa.com
DESCRIPTION
1"
STANDARD 90°
0.84 1.07 1.22 1.68 1.98 2.44 3.35 4.12 4.88
ELBOW
MEDIUM RADIUS
0.69 0.92 1.07 1.37 1.68 2.14 2.75 3.51 4.27
ELBOW 90°
LONG RADIUS
0.54 0.69 0.84 1.07 1.37
ELBOW 90°
STANDARD 45°
0.38 0.54 0.61 0.77 0.92 1.15 1.53 1.83 2.29
ELBOW
STANDARD TEE
1.68 2.29 2.75 3.36 4.28 5.19 6.71 8.23 10.1
ANGLE GLOBE VALVE
3.97 5.49 6.71 8.23 10.7 12.2 16.8 21.3 25.9
(OPEN)
GLOBE VALVE (OPEN)
7.93 10.7
GATE VALVE (OPEN)
0.19 0.25 0.29 0.38 0.43 0.54 0.69 0.84 1.07
INCREASER
1.21 1.52 1.82 2.74 3.35 4.26 6.09 7.92 10.1
REDUCER
0.3
SUCTION VALVE
0.91 1.21 1.52 2.13 2.74 3.35 4.87
DIAMETER
1¼"
1½"
2"
2 ½"
13
16.8 21.3 24.4 35.1 42.7 48.8
0.3
0.3
0.61 0.61
Installation
3"
4"
5"
6"
1.6
2.14 2.75 3.36
0.9
1.21 1.21 2.13
6.4
7.92
10