Euro-Pro EP171 Panduan Petunjuk Penggunaan dan Perawatan - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Petunjuk Penggunaan dan Perawatan untuk Besi Euro-Pro EP171. Euro-Pro EP171 9 halaman. Compact performer 115/230 v., 60hz., 800 w.
Shark Compact Performer
Model EP171
115/230 V., 60Hz., 800 W.
Main Components
1. Water Filling Inlet
2. Steam Control Dial
3. Spray/Burst of Steam Selector Button
4. Temperature Control Dial
5. Thermostat Light
6. Dual Voltage Switch
7. Spray Nozzle
8. Stainless Steel Soleplate
9. Water Measuring Beaker
1
TROUBLESHOOTING
PROBLEM
POSSIBLE REASONS & SOLUTIONS
• Make sure that the plug is securely in the socket.
Iron does not heat
• Temperature setting too low.
Turn to higher setting.
• This is normal.
Thermostat ready light
The light goes On and Off as the thermostat is
goes On and Off
switching the heating element On and Off to
maintain the selected temperature.
Some odor or small
• This is normal.
particles come out of
Follow instructions for first use and allow iron to steam
steam vents of new
through 2-3 fillings & press the steam burst button
iron
occasionally to eliminate small white particles.
Iron does not steam
• Water tank may be empty or water level is very low.
Add water.
• Make sure that the temperature control dial and
the steam control are correctly set. For
maximum steam, (setting 'Max' on steam control),
temperature control dial should be set on '•••'.
• Adjustable steam control is set on "0".
Always allow the iron to reach the selected
temperature with the adjustable steam control setting
at '0'. Make sure the temperature control dial is set in
the correct steam area, e.g. '•', and the steam control is
not on '0'. For more steam, turn temperature dial to
higher setting, e.g. '•••', and the steam control to 'Max'.
• If temperature setting and steam control setting are
correct and there is no steam, gently tap the
soleplate on the ironing board a few times. Move
the steam control from '0' to 'Max' a few times.
• Iron may not be hot enough. Set thermostat to the
Water droplets coming
'Max' position. Always allow iron sufficient time to
from steam vents
heat up (thermostat light goes off).
• Overuse of steam burst. Allow more time between
each burst.
• Iron may have been overfilled. Turn iron off,empty
water and follow instructions for filling.
• Steam performance may be low if iron requires
seasoning. To season, use regular tap water for 1or 2
tanks until steam performance improves.
10