Domus MURO-30S-B-W Panduan Instalasi - Halaman 3

Jelajahi secara online atau unduh pdf Panduan Instalasi untuk Sorotan Domus MURO-30S-B-W. Domus MURO-30S-B-W 4 halaman. Spotlight with sensor

Domus MURO-30S-B-W Panduan Instalasi
Adjusting the LUX control level: The Lux control module has a built-in sensing device (photocell) that detects
daylight and darkness. The ( ) position denotes that the Spotlight can work at day and night, and the ( )
position only work at night. You can set to operate the unit at the desired level by adjusting the LUX knob.
Adjusting the sensitivity: The sensitivity means the Maximum distance which PIR Sensor can be triggered by
movement body. Turning the SENS knob + to - will decrease the sensitivity.
Setting the controls
1. Put the Lux control knob to light ( ) position, turn the wall switch on and wait half a minute for the control
circuit to stabilize. At this stage ensure that the TIME control knob is set at minimum duration. The LED
lamp will now switch on and remain on for about 30 seconds (within 60 seconds).
2. Direct the sensor toward the desired area to be scanned by adjusting the elbow joint and swivel joint on
the sensor arm. Have another person move across the center of the area to be scanned and slowly adjust
the angle of the sensor arm until the unit sensors the presence of the moving person, causing the light to
switch on.
3. Adjust time control to required setting.
4. To set the light level at which the lights will automatically switch "on" at night, turn the LUX control knob
from daylight to night. If the lamps are required to switch on earlier, e. g. Dusk, wait for the desired light
level, then slowly turn the LUX control knob towards daylight while someone walks across the center of the
area to be detected. When the Spotlights switch on, release the LUX control knob. You may need to make
further adjustments to achieve your ideal light level setting.
How to change into MANUAL OVERRIDE CONTROL MODE
1. When power is on, the PIR detector enters into the "WARM-UP" periods for about 1 minute, then
automatically changes into AUTO MODE.
2. During AUTO MODE, by switching the ON/OFF main switch twice within 3 seconds and then switching it
on again, the PIR detector will automatically change into MANUAL MODE from AUTO MODE. In MANUAL
MODE, the Lamp(s) will remain ON, not affected by duration time and Lux control level.
3. During MANUAL MODE or AUTO MODE, by switching off the ON/OFF main switch for over 6 seconds and
then on again, the PIR detector will reset to WARM-UP periods. Please note: the periods of "WARM-UP"
maybe shorter than 1 minute.
POWER ON
1
3
MANUAL MODE
Specifications
Detection range: Max. 12 metres at 180°scan
Duration Time adjustment: (10±5) seconds to (4±1) minutes.
Detection circuitry: Passive Infra-Red (PIR)
Power required: 240V AC, 50HZ
Maximum load: 2x15Watt LED.
Weatherproof: IP44
AUTO MODE
2
29-31 Richland St. Kingsgrove. Sydney NSW 2208 Australia
Phone: 02 9554 9600
|
Fax: 02 9554 9433
|
www.domuslighting.com
Installation Manual